paper size: scale: material: finish: description: revision: drawing number: 400 [15.748] 282 [11.102] 240 ctrs [9.449] 226 ctrs [8.898] 237,4 i/s [9.346] 350 i/s [13.780] r typ. 2 .079 [ ] 256 ctrs [10.079] 216 ctrs [8.504] 4-off 6 .236 [ ] 4-off m6 pemserts to be fitted securely (see end view for orientation) 9 .354 [ ] 340 [13.386] 50 o/s [1.969] 20 o/s [.787] 1,5 [.059] b sheet 1 of 1 0.500 a3 A70-000629 recessed ceiling mount -- wpa support frame self zintec 1.5mm this drawing and all information contained is the property of dialight. unauthorised copying or disclosure is forbidden. all dimensions in mm [inches.] imperial dimensions are for reference only, don't use for machining. features coloured in red to be checked during goods in inspection. unless otherwise stated tolerances: x=0.5mm, x.x=0.2mm, x.xx=0.1mm, angles: 1 dialight 13-sept-2010 ft dw gea cjg 52mm -> 50mm clamp depth 301 b 20-jul-2010 ft dw gea cjg first issue a date q.c. app'd check drawn description ecn # rev index part number description quantity 1 a70-000628 " support frame -- recessed mount wpa - - " 1 2 a78-001188 " m6 threaded pemsert - - " 4 notes: 1. please refer to 3d cad file for additional dimensions. file issue must match drawing issue. 2. no changes without dialight engineering approval. 3. only rohs and reach compliant material accepted. 4. rivnuts to be securely fixed to metalwork 0.150 scale 1 2
|